Division 2 Rules are Safer and Save Money

Did you know you can design safer and save money using ASME Division 2 rules instead of Division 1? 

There are many ways to take advantage of the higher allowables and more accurate numerical methods in Division 2. One such method to consider is using the Bildy Rules instead of Area of Replacement for nozzle design. 

Take a look at this simple nozzle internal pressure case:

Design Pressure = 290 psi (2000 kPa)

Design Temperature = 475°F (246°C)

Nozzle Material = SA-106 C Smls Pipe

Nozzle Size = NPS 12 Sch 140

The Division 1 vessel does not pass the design condition of 290 psi (2000 kPa) @475°F (246°C).

The Division 2 vessel passes the design condition of 290 psi (2000 kPa) @475°F (246°C).

I recommend against designing with nozzle reinforcing pads whenever possible. This is one simple example where a nozzle reinforcing pad is avoided by using Division 2.

Save Money and Design Safer with Division 2 Nozzle Rules
Previous
Previous

Appendix 46 for Large, Non-Radial Nozzles

Next
Next

Use Division 2 Nozzle Rules with Appendix 46