Finding ASME B16.5 Blind Flange Bolt Load

Finding ASME B16.5 Blind Flange Bolt Load

Having a difficult time figuring out the Bolt Load (W) for your modified ASME B16.5 blind flange? Check the flange it is attached to!

Oftentimes ASME B16.5 blind flanges used as reducers include pipes larger than allowed in B16.5 without a reinforcement calculation. I have found that the additional bolted cover calculation trips up some designers as they were expecting the ASME B16.5 blind flange to be exempt. The most common reason people reach out to me is for help finding the Bolt Load (W) needed in the bolted cover required thickness calculation.  

Please remember that mating pairs share the Bolt Load (W). This means that finding the Bolt Load (W) needed for the bolted cover required thickness calculation may be as simple as grabbing it from the flange it is attached to.

Read More
Simple Gasket Look-Up in COMPRESS

Simple Gasket Look-Up in COMPRESS

Do you spend too much time looking up Gasket Factor (m) and Gasket Seating Stress Factor (y) values?

Whenever someone asks me to design a custom Appendix 2 or Part 4.16 flange I want to know the m and y factors of the gaskets they intend to use. A lot of times this crucial gasket design information is tough to track down. Thankfully COMPRESS has a great selection of pre-loaded gaskets to choose from including manufactures like Garlock, Flexitalic, Lamons, and Teadit. 

Use a manufacturer not listed in COMPRESS? It is easy to add new gaskets to the pre-loaded database.

Read More