Having issues sealing at your cover plate or blind flange? The issue may be with the cover plate and not the flange. Please remember that a little plate thickness goes a long way!
ASME B16.5/16.47 blind flanges are popular as heat exchanger cover plates and pressure vessel blind flanges. However, the default thicknesses of these standard ASME B16.5/B16.47 plates may be causing leaks from operational flange rotation at the diameter at the location of the gasket load reaction, G. This is because the differential pressure loading between the process side and the non-process side creates rotation across the plate.
Fortunately, this issue can be easily rectified by using a custom blind flange with a little extra thickness. Adding a little thickness greatly reduces the operational rotation due to differential pressure loading because the thickness is cubed in the required thickness equation.
Consider the Maximum Permissible Flange Rotation, 𝛳gmax in piping, pressure vessel, and heat exchanger designs with cover plates and blind flanges.